CADR for a 1,200 sq ft room

Quick answer

Start from the volume: 1,200 square feet at an eight foot ceiling is 9,600 cubic feet of air. It needs about 720 CFM of clean air delivery rate to reach four and a half air changes an hour, which is the range usually suggested where somebody in the house has allergies, 320 CFM for two changes an hour, and 960 CFM for smoke season at six. AHAM's two thirds convention gives 800 CFM for this room, which is the same arithmetic with an eight foot ceiling and five air changes an hour already filled in.

CADR figures come from the ANSI/AHAM AC-1 test method. The air change targets are guidance, not a standard.

Required clean air delivery rate for 1,200 sq ft, eight foot ceiling
TargetAir changes an hourRequired CADRTime to remove 90 percent
General air quality2320 CFM69 min
Allergy households4.5720 CFM31 min
Five changes, the two thirds convention5800 CFM28 min
Smoke and wildfire season6960 CFM23 min
Meets 720 CFM, the extra large room class

MOOKA Air Purifiers for Home Room up to 1076ft2, True HEPA Filter, B-D02L

This machine can be credited with about 861 CFM, derived from the listing's own figures: 1076 sq ft at 6 air changes an hour, assuming an eight foot ceiling. That clears the 720 CFM this room needs for four and a half air changes an hour.

$49.99Check pricePrices change often

Coverage claims vary in what air change rate they assume, so compare a published airflow figure rather than the room size on the box.

The same room at other ceiling heights
CeilingVolumeCADR at 2 ACHCADR at 4.5 ACHCADR at 6 ACH
7 ft8,400 cu ft280 CFM630 CFM840 CFM
8 ft9,600 cu ft320 CFM720 CFM960 CFM
9 ft10,800 cu ft360 CFM810 CFM1080 CFM
10 ft12,000 cu ft400 CFM900 CFM1200 CFM
12 ft14,400 cu ft480 CFM1080 CFM1440 CFM
What a coverage claim for this room would mean at each rate
If a listing says it coversAt this rateThat implies an airflow of
1,200 sq ft1 air change an hour160 CFM
1,200 sq ft2 air changes an hour320 CFM
1,200 sq ft4 air changes an hour640 CFM
1,200 sq ft5 air changes an hour800 CFM

How much airflow does a 1,200 sq ft room need?

The arithmetic is one line. Required CADR in cubic feet per minute equals floor area times ceiling height times the air changes you want, divided by sixty. For 1,200 square feet at eight feet, four and a half changes an hour works out at 1,200 x 8 x 4.5 / 60, or 720 CFM.

Nothing in that line is a rule of thumb. It is unit conversion: cubic feet of room, divided into minutes. The only judgement is the air change target, and that is where guidance rather than measurement comes in.

Why the two thirds rule gives the same number

AHAM publishes a shopper's convention: look for a smoke CADR of at least two thirds of the room's floor area. For this room that is 800 CFM. It is not a separate recommendation, it is this same calculation with two values already chosen for you, an eight foot ceiling and five air changes an hour, because 8 x 5 / 60 works out at 0.667.

That matters in two directions. If your ceiling is higher than eight feet, the convention quietly undersizes: at a ten foot ceiling this room needs 1000 CFM for the same five changes, not 800. And if two changes an hour is genuinely enough for your situation, the convention oversizes by more than half.

Reading a coverage claim for a room this size

A listing that says it covers 1,200 square feet has told you almost nothing on its own, because the number depends entirely on the air change rate the manufacturer chose. The same machine is honestly described as covering a large room at one change an hour and a much smaller one at five.

Where a listing states both the area and the rate, the airflow follows by arithmetic and you can compare machines properly. Where it states only an area, the useful move is to treat it as a ceiling rather than a specification, and to look for a published CADR instead.

How long it takes to clear the air

Particle removal in a well mixed room is exponential decay, not a countdown. At 720 CFM in this room the machine delivers four and a half air changes an hour, which removes ninety percent of what is airborne in about 31 minutes and ninety nine percent in about 61 minutes.

That assumes the machine is the only removal path and that nothing new is arriving. During cooking or on a smoke day both assumptions fail, which is the real argument for sizing above the comfort target rather than at it.

When one machine is not the answer

If the required airflow is higher than anything a single unit publishes, two smaller machines in different parts of the room beat one that cannot do the job. Two units also mix the room better, because a single unit in a corner recirculates its own clean air and leaves the far side of the room largely alone.

The other honest answer is to make the room smaller. A door closed during the hours you care about, usually while sleeping, cuts the volume the machine has to serve and does it for free.

Machines that publish enough airflow for 1200 sq ft

Every machine here has either a published CADR or a coverage claim that states the air change rate behind it, so the figure can be compared with the requirement above.

Common questions

What size air purifier do I need for a 1,200 square foot room?

About 720 CFM of clean air delivery rate for four and a half air changes an hour, or 320 CFM if two changes an hour is enough for your situation. The figure comes from floor area times ceiling height times air changes divided by sixty. With an eight foot ceiling this room holds 9,600 cubic feet, so the machine has to move that volume through a filter four and a half times each hour.

Is CADR the same as CFM?

They share a unit but they are not the same claim. CFM is how much air a fan moves. CADR is how much of that air comes out genuinely cleaned, measured under the ANSI/AHAM AC-1 test method in a sealed chamber. A machine can move plenty of air through a poor filter and post a high fan rating with a much lower CADR, which is why the tested figure is the one worth comparing.

Why does a purifier have three CADR numbers?

Because AHAM AC-1 measures three particle sizes separately: smoke, dust and pollen. Smoke is the smallest and usually produces the lowest number, so it is the one to compare when smoke is the reason you are buying. A single headline figure with no particle named is usually the highest of the three.

Does the ceiling height really change the answer?

Yes, proportionally. The calculation is about volume, not floor area, and the floor area only stands in for volume when the ceiling is the assumed eight feet. This room needs 720 CFM at eight feet and 900 CFM at ten for the same four and a half changes an hour, which is a difference big enough to change which machine you buy.

What if the room opens into a hallway?

Then the machine is serving a larger volume than the floor plan says, and it will fall short of the rate you calculated. Either size for the connected volume, close the door during the hours that matter, or accept a lower effective air change rate and know that is what you have chosen.